Feature:1.Contact switch current 100A
2. Compression between contact and coil is 5KV
3.Using metal magnetic shield structure, relay against strong magnetic interference
4.Energy conservation and environmental protection
Appliance:Widely appliance to single-phase energy meter, combination switch, streetlights, industrial automation control.
Dimension:52*52*25
Specification Data:
Coil Rated Voltage (V) | 9 | 12 | 24 |
Coil Resistance(Ω)±10% | Single 54 Double 22/32 | Single 70 Double 28/42 | Single 200 Double 100/100 |
Coil Pulse Drive Voltage Amplitude | ≥120% Rated Voltage | ||
Coil Pulse Drive Width | 40mS Min 100mS Max | ||
Coil Power | Single coil 1.5W Double coil 3/3 W | ||
Rate Switch Current | 100A | ||
Rate Switch Voltage | 250VAC | ||
Rate Current Contact Pressure drop | 60mV Max | ||
Contact Switch Time | 20mS Max | ||
Ambient Temp | -40-80°C | ||
Vibration | 10-55Hz Single Amplitude 0.75mm | ||
Impact | 147 m/S² | ||
Relative Humidity | 45%-85% | ||
Life(Mechanical) | ≥1×10 | ||
Life(Electrical) | ≥1×104 | ||
Max Operate Frequency | 600 OPS/H | ||
Dielectric Strength(Between open contact) | 2000VAC 50/60Hz | ||
Dielectric Strength(Between coil & contact) | 3750VAC 50/60Hz | ||
Insulation Resistance | 1000MΩ (500VDC) |
Notice
1.Relay is on the "reset" or "set" status when being released from stock, with the consideration of shock risen from transit and relay mounting, relay would be changed to "se" or "reset" status, therefore, when application (connecting the power supply),please reset the relay to "set" or "reset" status on request.
2. In order to maintain "set" or "reset" status, energized voltage to coil should reach the rated voltage, impulse width should be 5 times more than "set" or "reset" time. Do not energize voltage to "set" coil and "reset" coil simultaneously. And also long energized time(more than 1 min) should be avoided.
3. In order to avoid changing operate voltage, products should not be kept in strong magnetic field during transportation, storage and application.
Anti-theft DC Relay 12v WJ1-100A